  1. Plug the Service Stick USB to the IOT2050 Edge Device.

  2. The IOT2050 Edge Device must be powered on or restarted depending on its current situation:

    2.1. If the device is switched off, it must be powered on first then the Step 3 must be applied

    2.2. If the device is up and running, it must be restarted as in Step 3

  3. Press the 'Reset' button of IOT2050 Edge Device then keep on push 'User' button until you see the following message:

    "User button pressed - booting from external media only"

    User button pressed

  4. Wait for the main menu of the Service Stick.

    Main menu

  5. You may use UP and DOWN arrow keys to switch among the menu options. For selecting an item from the menu you must press Enter.

  6. To "Wipe Data & Reinstall" the operating system on the device, topmost item must be selected.

  7. For re-installation, appropriate .swu file must be present in the data part of the Service Stick USB

    SWU file

  8. During the installation process, a dialog to inform about the progress will be shown as follows:

    Progress

    If Service Stick USB does not a have valid swu file for installation, an error dialog will be shown as follows

    Problem

  9. After successful completion, a progress dialog will be displayed as follows:

    Successful completion

  10. Press "Enter" to get back to the main menu.

  11. To check and use the newly installed OS, restart of the device is recommended. For rebooting the device, "Power Management" option must be selected from the main menu

    Power Management

    In the sub-menu "Reboot" option must be selected.

    Reboot

  12. After the reboot operation the newly installed version of the OS can be verified as follows:

    Check installation