Verision 3.1.1.3-x86-64 (latest) - Manual - Industrial Edge - Industrial Edge - Industrial Edge - Documentation of the Industrial Edge Platform - IEM - Hub - Industrial - Device - IED - Edge - IEH

Industrial Edge Platform Operation - What's New?

Portfolio
Industrial Edge
Product
Industrial Edge
Software version
v26.01
Edition
01/2026
Language
English
Title Description
Firmware name simatic-ipc-ied-os-3.1.1-3-x86-64
Industrial Edge Device Kit version 1.24.2-1,You can find more information from [IEDK Release Notes]
Docker version 20.10.24
Operating system Debian: v12 (Bookworm), Kernel: 6.1.111-cip29-rt15+ind1, NVIDIA Driver:525.85.12-1, CUDA Driver:12.0
Release date January, 2026
What's new? The SIMATIC IPC Industrial Edge Device Operating System (SIMATIC IPC IED-OS) V3.1.1 supports only SIMATIC IPC BX-59A device type and includes the following bug fix:
  • Fixed the issue where GPU applications could loose GPU access after a power cut or reboot of the device.
Known Issues The following are the known issues:
IssueTroubleshooting
Connecting an Edge Device to the IEM fails and the "Nginx configuration test failed" error message is displayed during activating the Edge Device phase.Check the DNS server configuration since the error message is DNS server related.The DNS server must be configured properly and reachable for the IEM.
In case user data of edge device is corrupted due to unexpected power-outage or forcibly shutdown of edge device. IED-OS filesystem recovery process is going to take place.The process might take 2-3 hours depending on hardware specification of the running device.-
Sporadically, the Edge Device might stuck during the boot phase when you perform a firmware update.Switch off the Edge Device and switch the Edge Device on again manually. After switching on the Edge Device, the Edge Device will boot from the previous firmware version.After that, you can again trigger the firmware update process.
In case several apps are being installed at the same time, it takes a while to reach the Edge Device UI.Wait for a while to reach the Edge Device UI.
During firmware update IED might fail to activate device due to a failure in IE Device Catalog service and might getstucked in Activating state.The device should be rebooted. It is expected that the device would boot from the previous firmware. Firmware update should be triggered again.
Depending on the restart policies of the apps, the apps might not restart automatically after the reboot (includes also firmware update since it reboots the device).These apps should be manually started.
IED can have two selected Gateway Interfaces when one network interface configured as Gateway Interface from IED UI before onboard and another network interface configured as Gateway Interface during the creation of Edge Device configuration file in IEM.While connecting the IPC Edge Device, Pre-Onboard Network Configurations made from IED UI should be checked in order to perform a flawless connection with New IPC Edge Device Onboarding Network Configurations generated from IEM.
After network settings change from static IP to DHCP via Device UI, it takes a while to finalize the setting of new IP.Wait for a while to see the new IP settings.
If you set the IPs on the same subnet for network interfaces, one of the connections may be broken.Do not set more than one IP on the same subnet.
Fixed issues The following bugs have been fixed with SIMATIC IPC IED-OS V3.1.1:
  • You can find the new features and bug fixes of IEDK via the following link: Industrial Edge Device Kit v1.24
Other information The supported Edge Devices, including their non-functional requirements (NFRs), is SIMATIC IPC BX-59A (MLFB - 6AG4133-0****-W*).

The NFR values are different depending on the device configuration.

Estimated Drive Writes Per Day (DWPD) for supported Edge Devices are the following:

Device TypeStorage SizeDWPDDaily Write Capacity
SIMATIC IPC BX-59A1 TB0.43500 GB/day