Extended sub-status "UNCERTAIN" (sub-status (bits 8..11)) - Manual - SLMP Connector - Industrial Edge - Industrial Edge App - SLMP provides easy connectivity with third party PLCs communication channel for tags. You can use the configured connections to transfer the measured value series of selected data points to the Runtime of the respective IED. - Mitsubishi iQF Services - SLMP Connector - TIA Portal - Mitsubishi iQR Services

SLMP Connector

Portfolio
Industrial Edge
Product
SLMP Connector
Software version
v2.1.0
Edition
03/2023
Language
English
Value Meaning Description
0 Non-specific No CHROM specific extended uncertain sub-status is associated with this value.
1 Aggregated value The value has been calculated out of multiple values with less than the required number of good sources to be GOOD as well as less than required number of bad sources to be BAD. This includes data aggregation by means of data compression algorithms. The corresponding sub-status is set to 'non-specific'.
7 Disabled The provider of the value (logging tag for logged value) has been disabled and the previous value was GOOD or UNCERTAIN. In case of GOOD, the corresponding sub-status is set to 'last usable value'. In case of UNCERTAIN, the corresponding sub-status is taken from the last (previous) sub-status.