To configure CIP analysis, proceed as follows:
- Select an asset in My Plant.
- Click
Add dashboard. - Select
CIP dashboard.
The "CIP configuration" view appears..
- Select the default time period.
The periods defined underConfigurationare available for selection. - Select a calculation cycle.
The selected calculation cycle will be used for parameters and their respective influence in the scoring. - Select the parameter that represents the needed contexts.
For CIP analysis there are multiple contexts that are possible. CIP ID represents the unique identifier of a process that shall be monitored. Process ID represents the type of cleaning process that has been started - this is an optional parameter.
Step ID represents the different phases of a cleaning process - this is an optional parameter. - Select the parameters that represent the cleaning process.
Temperature, Concentration, Flow Rate and Pressure are mandatory for CIP analysis configuration. - Select one or more parameters to be analysed in addition.
The parameters can represent, for example, various cost factors (energy consumption, cost of raw materials) or consumption values. - Click
Save.
An automatically generated dashboard is created which is continuously supplied with data.
The "CIP" dashboard is displayed.