When you perform a hard reset or a reboot of the SIMATIC IPC BX-59A, it may happen that the event fails and an error occurs on the SIMATIC IPC BX-59A with 3 LEDs lighting up red on it.

In that case, you must open the BIOS menu of the SIMATIC IPC BX-59A and set the xHCI Mode to disabled in the Power > XHCI USB Wake Capability BIOS settings.

After you updated the BIOS settings, you can again perform a hard reset or a reboot of the SIMATIC IPC BX-59A.

Opening the BIOS menu

You open the BIOS menu by pressing and holding <Esc> after you switch on the SIMATIC IPC BX-59A.