List of all LED status - Manual - SIMATIC IPC IED-OS - SIMATIC - Industrial Edge

SIMATIC IPC IED-OS

Product
SIMATIC IPC IED-OS
Product Version
v2.3
Edition
10/2024
Language
en-US (original)

The following table lists all LED status changes of the Edge Device during several processes:

Process Description Power Run Error Maintenance
Not connected to the IEM When the Edge Device is not connected to the IEM, the Run LED flashes green. Green Green flashing Off Off
Connecting to the IEM When the Edge Device is connecting to the IEM (after the USB flash drive is inserted), the Run LED flashes green and the Maintenance LED flashes orange. Green Green flashing Off Orange flashing
Connection to the IEM was successful When the Edge Device is connected successfully to the IEM, the Run LED lights up green. Green Green Off Off
Connection to the IEM failed When the connection to the IEM has failed, the Error LED flashes red. Green Off Red flashing Off
IED-OS updates When IED-OS updates are in progress, the Maintenance LED flashes orange. Green Off Off Orange flashing
During the hard reset of an Edge Device When a hard reset is triggered, the current status of the LEDs varies from device type to device type while the device is rebooting. Then, while the device is booting, the Power LED lights green for a while. At the end, only the Power LED will light green and the Run LED will flash green. - - - -
Hard reset was successful When the Power LED lights up green and the Run LED flashes green, the hard reset was successful. The Edge Device is not connected anymore to the IEM in this case. Green Green flashing Off Off
During the system reset of an Edge Device When a system reset is triggered, the current status of the status LEDs varies from device type to device type while the device is rebooting. Then, while the device is booting, the Power LED lights green for a while. At the end, only the Power LED will light green and the Run LED will flash green. - - - -
System reset was successful When the Power and Run LEDs light up green, the system reset was successful. The Edge Device is still connected to the IEM in this case. Green Green Off Off
Shutting down the Edge Device After you have shutdown the Edge Device, the Power LED lights up orange. Orange Off Off Off