The stored file on section Download Camera Configuration can be provided to the camera restoring the setup. File integrity and validations are recommended and shall be implemented by the connector application.

Message Envelope For ZMQ Message

Frame Field Description Type
1 payload Method payload Binary String (UTF-8)

payload

Field Optional Type Description
TransactionID Yes String Transaction identification.
Action No String Method called. Fixed value SetDeviceConfig
DeviceID No String Device identification.
FileContent No String Base64 string of the configuration file. Containing the mime type prefix.
{
    "TransactionID": "234423465465",
    "Action": "SetDeviceConfig",
    "DeviceID": "548451887",
    "FileContent": "data:text/plain;base64,IyB7MDVEOEMyOTQtRjI5NS00ZGZiLTlEMDEtMDk2QkQwNDA0OUY0fQojIEdlbkFwaSBwZXJzaXN0ZW5jZSBmaWxlICh2ZXJzaW9uIDMuMS4wKQojIERldmljZSA9IEJhc2xlcjo6QmFzbGVyQ2FtRW11IC0tIEJhc2xlciBDYW0gRW11IGludGVyZmFjZSAtLSBEZXZpY2UgdmVyc2lvbiA9IDEuMC4xIC0tIFByb2R1Y3QgR1VJRCA9IEI5N0RFNTQ5LUNCOUEtNDRmOC05MzdELTY0QzQ4QkRFQ0ZBMyAtLSBQcm9kdWN0IHZlcnNpb24gR1VJRCA9IEEyRENERTE0LTczRTQtNDA4YS1BRkE4LTgxODUyRUNCNUQ5QQpHYWluCTAuMDAwZSswMApXaWR0aAkxMDI0CkhlaWdodAkxMDQwClBpeGVsRm9ybWF0CU1vbm84CkV4cG9zdXJlVGltZQkxMDAwMC4wCg=="
}

Response

Frame Field Description Type
1 payload Response object Binary String (UTF-8)

Response Object

Field Optional Type Description
TransactionID Yes String Transaction identification.
ReturnCode No Integer Message code following Message Codes.
Message Yes String Response message
{
  "TransactionID": "234423465465",
  "ReturnCode": 0,
  "Message": "Configuration loaded."
}