publishType Message Type Message Example in principle Used by connector
single Data Point Payload (deprecated since V1.2, no longer supported for new installations) { seq, vals{ id, val, ts, qc } } SIMATIC S7 V1.1, Modbus TCP V1.0, Ethernet IP V1.0
bulk Data Points Payload (pubDpValueSimaticV1Payload) { seq, vals[ { id, val, ts, qc } ] } SIMATIC S7 V1.1/V1.2, PROFINET IO 1.1, Modbus TCP V1.0, Ethernet IP V1.0