To define widget-specific display options, follow these steps:

  1. Create a new widget or edit the existing one.
  2. In step 2, select a parameter which is visualized in the widget.
  3. Click 157453207819-d2e6789 and open the "Visualization" area.
    156472933643-d2e6795
  4. For variables, you specify how many decimal places are displayed.
  5. Select the color for the display of the parameter.
  6. Select the type of the visualization.

    • Line chart (Line)
    • Spline curve
    • Area chart (Area)
    • Bar chart (Bar)
      The columns of several parameters are displayed stacked.
    • Scatter chart (Scatter)
  7. Activate further options:

    • Select whether the value is to be visible.
    • With the bar chart, you can select whether the value is to be displayed stacked.
  8. In step 3 "Details", you define the display of the y axes.
    For KPI instances, select the calculation period.
    172877754123-d2e6854
    A y-axis is created for every unit that is assigned to a parameter. A maximum of 5 y axes can be defined per widget.
    Each parameter is automatically assigned to a y axis. However, you can also manually assign the parameters to a different y axis.
    You can define a low and high limit for each y axis. This means that you can only display a section between specific values in the widget.
    Alternatively, you can enable "Scale by values". When the display is zoomed, the Y-axis adapts to display the range of values present.