Software requirements - Manual - Connector for IEC 60870-5-104 - Industrial Edge - Industrial Edge App - Connector for IEC 60870-5-104 transfers data from IEC devices over TCP/IP network to the Databus or IIH, allowing the values of these tags to be analyzed and visualized in applications like Performance Insight. - Connectivity suite connector - Connector for IEC 60870-5-104 - Data transfer - IEC 60870-5-104 - International Electrotechnical Commission - TCP/IP network

Connector for IEC 60870-5-104

Product
Connector for IEC 60870-5-104
Product Version
v1.0.0
Edition
12/2024
Language
en-US (original)

The following Internet browsers are required:

  • Google Chrome, Version ≥ 72

The apps are available in the Industrial Edge Marketplace. From there, you can transfer the latest version of the app to your Industrial Edge Management (IEM) and then install it on your Industrial Edge Device (IED):

App/Component Required version Description Source
Common Configurator V1.11 or later You need this if, to configure the data sources and tags on IED. Industrial Edge
Marketplace
IIH Semantics V1.0 or later Optional
Industrial Edge
Marketplace
IIH Registry Service V1.8.0 or later It creates the connection between the individual components. Needed to view the connectors in the overview. Industrial Edge
Marketplace
IIH Essentials V1.10 or later Optional
Required if you want to store the data.
Industrial Edge
Marketplace
Common Import Converter V2.1.0 or later It is required for the conversion of different file formats to the IIH compatible format and to import the values of tags from a TIA Portal project offline. Industrial Edge
Marketplace
Connector for IEC 60870-5-104 V1.0 Mandatory Industrial Edge
Marketplace
Databus V3.0.0 or later Required if you want to publish the values of tags to the Databus. Industrial Edge
Marketplace
SIMATIC SCADA Export for TIA Portal TIA Portal V18 or later Required if you want to import the values of tags from a TIA Portal project offline. Siemens Industry Online Support (SIOS)

NOTE

  • All the above mentioned apps must be installed on the same IED.
  • The latest version of Databus V3.0.0 is capable enough to communicate to connectivity suite connectors as the Databus Gateway application is now integrated to Databus.