Error codes of the ModbusSlave - Manual - SIMATIC AX - Instructions that can be used for Modbus-RTU communication. - Siemens.Simatic.S71500.CommunicationsProcessor.ModbusRtu,library

Siemens.Simatic.S71500.CommunicationsProcessor.ModbusRtu library

Portfolio
SIMATIC AX
Product
SIMATIC AX
Software version
1.0.2
Edition
11/2024
Language
English (original)
Package Name
@ax/simatic-1500-modbusrtu
Error code Description
16#8180 Invalid value for MB_DB parameter
16#8186 Invalid slave station address
16#8187 Invalid value at holdingRegister parameter
16#8280 Negative acknowledgment when reading module
16#8281 Negative acknowledgment when writing module
16#8381 The function code is not supported or is not supported for broadcast.
16#8382 Invalid length information in the request frame
16#8383 Invalid data address in the request frame
16#8384 Invalid data value error in the request frame
16#8385 The diagnostic value is not supported by the Modbus slave (function code 08)