Parameters - Manual - PLC Control - The SIMATIC AX tool to manage connections to SIMATIC PLCs and run simple PLC operations like stop/run, alarms, diag, and mon/mod. - Connection Sharing And PLC Control Tool,tool

PLC Control CLI Tool (plc-control)

Portfolio
SIMATIC AX
Product
PLC Control
Software version
1.4.3
Edition
10/2025
Language
English (original)
Package Name
@ax/plc-control
Parameter Description
-t, --target The alias name or IPv4 address of the target.
-p,--password Password granting the access level to the target required for all following operations. For more information, refer to the security concepts.
-u, --username Define the user nameused to legitimate at the PLC for the UMAC feature of firmware V3.1 and above (refer to the documentation of TIA Portal V19). The user must be assigned the appropriate role for the online operations. A legitimation password must always be added if a username is used.
-C,--certificate Specify a file path to an X.509 certificate that the user wishes to validate their PLC against.
-T,--timeout Set a timeout after that the connection is automatically closed by the connection server. Default: 8 hours
The timeout can be set in two formats: HH:mm (e.g., 17:00) or hh.hour-fraction (e.g., 3.5). With the first format, the connection is closed at the exact time. The second format closes the connection after the specified duration.