2.1.0
|
OPC UA Connector support
Support for SIMATIC S7 Connector and SIMATIC S7+ Connector: additional data types
Support for 3rd party Vision Connectors
Writing data to PLC
Shared memory support between Docker containers and Linux processes with RIB
Updated user interface
Support for the Chinese language
|
2.0.0
|
Execution of AI models on GPU-accelerated hardware
Support for additional data types: ByteArray, SIntArray, Int8Array, Int16Array, RealArray (uses float32), LRealArray (uses float64)
Support for batch processing
Support of multiple Python versions (3.8.19, 3.10.14)
Support for retention of pipeline output data via the Databus
Simpler installation with the Edge application AI Model Manager
Adjustments for standardized image transport
Updated user interface
|
1.6.0
|
Option for enabling automatic restart of the app, which continues execution of the AI model after multiple reboots of the Edge device.
Support for the mass mapping of several identical inputs
Advanced filter options for log messages
Support for the ImageSet type
Support for wildcarded topics
Improvements to the user interface
Permanent storage for the pipelines
|
1.5.0
|
Support for execution of multiple pipelines (up to 3)
Versioning of pipeline packages based on the Package ID (UUID)
Option to send data to an external ZMQ server and receive data from an external ZMQ
Improvements to the user interface
|
1.4.0
|
Simplified setup of the data connection
Immediate log deletion
Writing the data (while using the multi-part message format) to external ZMQ
Removal of the standard connection
Display of data sources in the pipeline visualization
Generation of more than one data connection with the same data connection type and the same payload (although with different login information)
Improvements in debugging and logging
Improvements to the user interface
|
1.3.0
|
Simultaneous parallel step execution in the same pipeline
Support of Openness API
Inactivation of the pipeline
Improvements to the user interface
|
1.2.0
|
Updating the model/pipeline parameters on the user interface of the AI Inference Server before execution of the pipeline
Delta upload of the configuration package
Support of IE Vision Connector via Databus (MQTT) or directly via ZMQ
Support of application upgrade via Industrial Edge Management
|
1.1.0
|
Modification of the user interface
Support of multiple connectors
Automatic start function after restart
The AI model can retrieve data directly from various Edge connectors
Fine tuning for "internal" queue (ZMQ) per pipeline with App Config
Logging improvements
|
1.0.1
|
AI Inference Server version 1.0.1 is being launched on the market.
|