| ID | Category | Topic | Description |
|---|---|---|---|
| 1 | General Information | App version | Latest 1.0.0 (May 2024) |
| App artifact size (MB) | 1830 MB | ||
| Reserved memory (MB) | 1500 MB | ||
| Siemens Industrial Edge Management version (downward compatibility) | ≥ 1.16.1 | ||
| Industrial Edge Device version (downward compatibility) | ≥ied-os-2.1.0-22 | ||
| Application Installation and operation prerequisite | Layer 2 network configured on Industrial Edge Device | ||
| Application Instances per Industrial Edge device | One | ||
| Siemens Industrial Edge hardware | IPC 227E, IPC 427E, IPC 847E, BX-39A, BX-59A (only physical Industrial Edge devices are supported) |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 2 | User Interface | Main Features available via the UI | -Add/delete camera, Enable/disable camera, Connect selected industrial cameras (list of tested camera below), Connect RTSP camera, Unified cameras overview, Live camera stream image visualization (UI refresh rate limited to 25fps maximum), Setting camera parameters (industrial cameras only), Enabling/disabling cameras, Log visualization and download |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 3 | User Documentation | Language | English, German, Chinese |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 4 | Compatibility | Tested Industrial Cameras | Basler acA1300-60gc, Basler acA1600-60gm, Basler acA1920-25gc, Basler a2A2448-23gcBAS, Basler a2A2448-23gcPRO, Baslera2A2590-22g mBAS, Basler a2A2590-22g mPRO, Basler acA4024-8gc, Basler a2A4096-9gcBAS, Basler acA5472-5gc |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 5 | Camera connectivity | Multiple Camera Support | Yes |
| Max Simultaneous Camera | Dependent on camera configuration and network capacity. Note: The maximum number of cameras that can be simultaneously used depends on camera configuration (frames per second), Pixel Format, Resolution, available host, and network link capacity available on the layer 2 network used for camera connection.) |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 6 | Debug Usability | Log levels | Info, Warning, Debug, Error |
| Filtering | Possibility of filtering by debug level and by source, or you can use a free-text-search in the UI | ||
| Persistent logs retention period | 30 days | ||
| Logs Download | Yes (as compressed archive) |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 7 | Benchmark results | Benchmark results | Benchmark results presented here are only for reference and will be extended to additional types of Siemens Industrial Edge Devices and reference models for future versions |
.
| ID | Category | Topic | Description |
|---|---|---|---|
| 8 | Known issues | Known issues | Under certain camera setup conditions (hardware triggered, non-optimal network, multiple cameras) frame loss is possible and logged in log file. |
.