Geräte-ID - Manual - Industrial Edge - Industrial Edge - Industrial Edge - Documentation of the Industrial Edge Platform - IEM - Hub - Industrial - Device - IED - Edge - IEH

Industrial Edge Platform Operation - APIs & Referenzen

Portfolio
Industrial Edge
Product
Industrial Edge
Product Version
v25.04
Edition
04/2025
Language
de-DE
// ------------------------------------------------------------------
// Common Definition of Device Identifiers
// ------------------------------------------------------------------

syntax = "proto3";

import "common_address.proto";

package siemens.common.identifiers.v1;

//===================================================================
// Identifiers Interface Definitions
//===================================================================

// ===========================================
// The Services Definition
//
service IdentifiersApi
{
    rpc GetIdentifiers( GetIdentifiersRequest ) returns( GetIdentifiersResponse ) {}
    rpc GetSupportedSemantics( GetSupportedSemanticsRequest ) returns( GetSupportedSemanticsResponse ) {}
}

// ==================================================================
// Get Identifiers Request
//
// Get specific identifiers, identified by their semantic meaning from a device (connection)

message IdentifierRequest {
    oneof identifier {
        // The specific identifier which is requested
        SemanticClassifier semantic = 1;
        // if a Identifier does not have a semantic mapping we can use the name of it as fallback
        string name = 2;
    }
}

message GetIdentifiersRequest {
    siemens.common.address.v1.Destination target = 1; //the device to which the nodes/data points belong
    repeated IdentifierRequest identifiers = 2; // if no specific identifiers are provided, all supported identifiers (see GetSupportedIdentifiers) are returned
}

message GetIdentifiersResponse {
   repeated DeviceIdentifier identifiers = 1;
}

// ==================================================================
// Get supported identifier
//
// Get the list of identifiers and their semantic meaning which are supported by the connector

message GetSupportedSemanticsRequest {
    // void
}

message GetSupportedSemanticsResponse {
  repeated SupportedSemantic supportedSemantic = 1;
}

// ==================================================================
// Identifier definitions
//

// This message type is defined to work-around missing
// support for "repeated oneof" in gRPC. See
// https://github.com/protocolbuffers/protobuf/issues/2592
// for further reference.
message DeviceIdentifierValueList {
    repeated DeviceIdentifier value = 1;
}

message DeviceIdentifier {
    // The RAW value of the identifier, read from the device (connection)
    oneof value {
        // Transfer any integer value up to 64 bit
        int64 int64_value = 2;
        // Transfer any unsigned integer value up to 64 bit
        uint64 uint64_value = 3;
        // Transfer any floating point value
        double float64_value = 4;
        // Transfer a UTF8-text
        string text = 5;
        // Raw data
        bytes raw_data = 6;
        // A list of child identifiers. This value type
        // can be used to transfer structured, hierarchical
        // information.
        // Example: Ethernet interface (parent identifier) with
        // its assigned IP addresses (child identifiers) and MAC
        // address (another child identifier).
        DeviceIdentifierValueList children = 7;
    }

    // List of semantic mappings for this identifier
    repeated SemanticClassifier classifiers = 8;
}

message SupportedSemantic {
    // Human readable name of the identifier, e.g. "Manufacturer"
    string name = 1;
    // List of semantic identifiers
    repeated SemanticClassifier classifiers = 2;
}

message SemanticClassifier {
    // The type of the semantic identifier
    // supported default classifier:
    // "IRDI": e.g. for "CDD" or "eClass" classifier)
    // "URI": e.g. for JSON-Link
    string type = 1;
    // The value of the semantic identifier, e.g. "0112/2///61987#ABA565#007" (IEC CDD/IRDI "Manufacturer")
    string value = 2;
}
Art der Meldung Feld Typ Beschreibung
IdentifierAnfrage semantisch SemanticClassifier Die spezifische Kennung, die angefordert wird
name string Wenn ein Identifier keine semantische Zuordnung hat, können wir den Namen als Fallback verwenden
GetIdentifiersAnfrage Ziel siemens.common.address.v1.Destination das Gerät, zu dem die Knoten/Datenpunkte gehören
Bezeichner wiederholter IdentifierRequest Wenn keine spezifischen Bezeichner angegeben werden, werden alle unterstützten Bezeichner (siehe GetSupportedIdentifiers) zurückgegeben
GetIdentifiersResponse Bezeichner wiederholter DeviceIdentifier -
GetSupportedSemanticsResponse (Englisch) unterstütztSemantik wiederholtes SupportedSemantic -
DeviceIdentifierValueList value wiederholter DeviceIdentifier -
Geräte-Kennung int64_value int64 Übertragen Sie beliebige Ganzzahlwerte bis zu 64 Bit
uint64_value uint64 Übertragen Sie jeden vorzeichenlosen Ganzzahlwert bis zu 64 Bit
float64_value double Übertragen eines beliebigen Gleitkommawerts
Text string Übertragen eines UTF8-Textes
raw_data Bytes Rohdaten
Kinder DeviceIdentifierValueList Eine Liste von untergeordneten Bezeichnern
Klassifizierungen wiederholter SemanticClassifier Liste der semantischen Zuordnungen für diesen Bezeichner
UnterstützteSemantik name string Für Menschen lesbarer Name der Kennung, z. B. "Hersteller"
Klassifizierungen wiederholter SemanticClassifier Liste der semantischen Identifikatoren
SemanticClassifier type string Der Typ des semantischen Bezeichners
value string Der Wert des semantischen Bezeichners